Infinity Cool (20-600 kW): air-cooled chillers
The new generation of industrial chillers with low-GWP refrigerant R454B
The Infinity Cool series is the new flagship from Friulair: air-cooled chillers from 20 to 600 kW, designed around the low-GWP refrigerant R454B (GWP 467, safety class A2L). The range counts 27 models in two groups: IFC 021 to 105 kW and IFC 110 to 600 kW. Two configurations cover different processes: WLT for low-temperature chilled water (down to -8 °C) and WHT for high-temperature applications.
Because R454B is an A2L refrigerant, the units are intended for outdoor installation only. In the 20 to 200 kW range, refrigerant leak detection, safety valves and emergency ventilation are provided. Electronic expansion valves and EC fans are standard across the whole range, where this used to vary per series.
Heat recovery is available in detail: variable from 0 to 100% on IFC 021 to 105, and on IFC 110 to 600 either partial (around 20% of the cooling capacity) or full (around 100%). The range is also extensively configurable with pump and tank combinations, antifreeze heaters, sound-attenuating enclosures, connection kits and packaging options.
Infinity Cool succeeds the earlier Friulair chiller ranges CWB, CWB FC, CFT, CWE, CEN, HEN, CWT and CWV. Still running one of those units? We advise on the replacing Infinity Cool version and on parts and service for as long as your existing unit stays in operation.
- 27 models in two groups: IFC 021 to 105 kW and IFC 110 to 600 kW
- EC fans, electronic expansion valves and microchannel condensers as standard
- New generation controller with Infinity Core software and predictive diagnostics
- Modbus RTU (RS485) and Modbus TCP, BACnet/IP, MQTT and SNMP
- IEC 62443-4-1 certified cybersecurity, in line with CRA and NIS2
- Heat recovery 0 to 100% (IFC 021-105), partial or full (IFC 110-600)
- Leak detection, safety valves and emergency ventilation from 20 to 200 kW
- Outdoor installation only, extensively configurable
- Water Low Temperature
- 35/12/7 °C en 35/-4/-8 °C
- Water High Temperature
- 35/12/7 °C en 25/20/15 °C
Communication: Modbus RTU (RS485), Modbus TCP, BACnet/IP, MQTT, SNMP
27 models in the Infinity Cool series
| Model | Cooling capacity (kW) | EER | SEPR HT |
|---|---|---|---|
| IFC021 | 20.1 | ||
| IFC026 | 25.3 | ||
| IFC035 | 35.6 | ||
| IFC036 | 33.5 | ||
| IFC040 | 42.2 | ||
| IFC041 | 38 | ||
| IFC050 | 50.2 | ||
| IFC051 | 50.1 | ||
| IFC055 | 54.2 | ||
| IFC065 | 66.4 | ||
| IFC070 | 71.1 | ||
| IFC090 | 86.5 | ||
| IFC105 | 104.1 | ||
| IFC110 | 109.7 | 3.3 | 5.9 |
| IFC125 | 129.7 | 3.1 | 5.9 |
| IFC150 | 156.2 | 2.8 | 5.6 |
| IFC175 | 188.7 | 3.2 | 6 |
| IFC200 | 208.6 | 3.1 | 5.9 |
| IFC225 | 225.6 | 3.2 | 5.6 |
| IFC250 | 253.5 | 3.1 | 5.6 |
| IFC275 | 280.6 | ||
| IFC300 | 304.2 | ||
| IFC350 | 350.6 | ||
| IFC400 | 405.4 | ||
| IFC470 | 483.7 | ||
| IFC540 | 537.5 | ||
| IFC600 | 587.5 |
Capacities at nominal catalogue conditions; final selection is based on your process.
Quotation or advice for Friulair Infinity Cool
We size to your process: capacity, temperature level, installation and operating hours. You receive a substantiated proposal within 1 working day.
Request a quote for this series