Redundant cooling as part of your uptime
We design with N+1 or 2N redundancy and concurrently maintainable components, so one machine can be serviced while the rest keeps running.

Redundant chillers, free cooling and direct liquid cooling for low PUE and high availability. Including complete installation and certified piping.
A failed chiller in an office costs an afternoon of work. In a data centre the load stops, and with it the service to your own customers. That is why we design data centre cooling around availability: redundant components, concurrently maintainable layouts and controls that prioritise free cooling.
At the same time, cooling is the largest energy cost after the IT itself. Free cooling, high water temperatures and, where it fits, direct liquid cooling visibly lower the PUE. Availability first, consumption right after.
We design with N+1 or 2N redundancy and concurrently maintainable components, so one machine can be serviced while the rest keeps running.
In the Dutch climate, free cooling handles most of the year without compressors, with adiabatic support for the hottest days.
Above roughly 30 kW per rack we supply direct liquid cooling with a CDU and manifolds, connected to a redundant chilled water circuit.
Maintenance windows follow your change management. Monitoring reveals trends before a failure occurs.
Every data centre installation is custom engineered and therefore quoted on request. We can deliver the complete project, including engineering, assembly and piping.
Capacity calculation, N+1 or 2N design, hydraulic schematics and alignment with your uptime requirements.
Process water, glycol and refrigerant piping to applicable standards, including certified welding where required.
Placement, connection, pressure testing, flushing, filling, functional tests and controlled handover.
Connection to building management and component-level monitoring, with maintenance aligned to change management.
Pricing is determined per project based on capacity, redundancy, pipe routes, accessibility and required monitoring.
Request a project quoteAir-cooled chillers 21 to 600 kW with EC fans and free cooling version, for outdoor installation.
View the seriesDry coolers for free cooling and adiabatic support, the engine behind a low PUE.
View the seriesWide range of cooling units, suitable for separated circuits and custom setups in critical rooms.
View the seriesSelection depends on your rack density, setpoint and location. The configurator shows which models fit. Configurator
Compact outdoor cooling units with free cooling and remote monitoring.
Connection to process cooling water with separated circuits, so a production failure does not affect the server room.
Stable temperatures with redundant units and monitoring, also when replacing existing systems.
Every project is different. Capacity, redundancy, pipe routes, layout and controls determine the price. After an assessment, you receive a quote for supply and, if required, complete installation.
PUE is total energy use divided by IT energy use. With prioritised free cooling and adiabatic support, a PUE below 1.3 is realistic in the Netherlands.
With N+1 one spare component covers the failure of one machine; with 2N the full capacity is duplicated. Maintenance can then happen without interruption.
From roughly 30 kW per rack, air cooling is barely efficient. We then remove heat directly via liquid with a CDU and manifolds.
Yes. Via Modbus, BACnet or MQTT we track temperature, pressure and consumption at component level and intervene before a failure occurs.
Tell us about your cooling capacity, redundancy requirement and location. Within 1 business day you receive a first estimate and an indicative design.